Hydraulic Valve Direction

1x FLOATING 3 Bank Hydraulic Directional Control Valves 80L 21 gpm DA ex February 25, 2025

1x-FLOATING-3-Bank-Hydraulic-Directional-Control-Valves-80L-21-gpm-DA-ex-01-yrr 1x FLOATING 3 Bank Hydraulic Directional Control Valves 80L 21 gpm DA ex
1x FLOATING 3 Bank Hydraulic Directional Control Valves 80L 21 gpm DA ex
1x FLOATING 3 Bank Hydraulic Directional Control Valves 80L 21 gpm DA ex

1x FLOATING 3 Bank Hydraulic Directional Control Valves 80L 21 gpm DA ex
NOTE: We issue VAT invoices for countries in the European Union. 3 BANK HYDRAULIC MONOBLOCK DIRECTIONAL SPOOL VALVE 3x Double Acting Cylinder +floating spool. Hydraulic distributors are guaranteed for 2 years. It is used in hydraulic systems in agriculture, horticulture, forestry, construction and industry. The distributor is adapted to different types of machines: agricultural machines, tractors, sprayers, front loaders, construction machines, loaders, excavators, sweepers, industrial machines and for other applications hydraulically controlled. Recommended oil flow in the system: 0-80L / min. Control example: double-acting hydraulic cylinder. Possibility of series connection to the existing system (requires connection of a pressure sleeve). Three-position lever (1-0-2), spring-loaded, ie it moves back into the vertical position. Neutral position 0 (lever up), piston rod of the hydraulic cylinder is stationary – oil overflows. Working position 1 (lever up), the piston rod of the hydraulic cylinder slides out. Working position 2 (lever up), the piston rod of the hydraulic cylinder retracts. Pump supply (P): female thread BSPP 3/4 ” (Sometimes BSPP 1/2″). Return to tank (T). Female thread BSPP 3/4. Output for sections (A, B). Female thread BSPP 1/2. Pressure range Maximum supply pressure: 250 bar. Maximum return pressure: 50 bar. Maximum pressure in sections: 300bar. Bypass valve (safety) set at the factory to 175 bar. Self-adjusting, full turn 30 bar displacement. Permissible ambient temperature: 40 ° C to + 60 ° C. Permissible oil temperature: 15 ° C to + 80 ° C. Dimensions can be changed slightly.
1x FLOATING 3 Bank Hydraulic Directional Control Valves 80L 21 gpm DA ex
Comments Off

1x FLOATING 3 Bank Hydraulic Directional Control Valves 80L 21 gpm Double Acting

1x-FLOATING-3-Bank-Hydraulic-Directional-Control-Valves-80L-21-gpm-Double-Acting-01-cldy 1x FLOATING 3 Bank Hydraulic Directional Control Valves 80L 21 gpm Double Acting
1x FLOATING 3 Bank Hydraulic Directional Control Valves 80L 21 gpm Double Acting
1x FLOATING 3 Bank Hydraulic Directional Control Valves 80L 21 gpm Double Acting

1x FLOATING 3 Bank Hydraulic Directional Control Valves 80L 21 gpm Double Acting
NOTE: We issue VAT invoices for countries in the European Union. 3 BANK HYDRAULIC MONOBLOCK DIRECTIONAL SPOOL VALVE 3x Double Acting Cylinder +floating spool. Hydraulic distributors are guaranteed for 2 years. It is used in hydraulic systems in agriculture, horticulture, forestry, construction and industry. The distributor is adapted to different types of machines: agricultural machines, tractors, sprayers, front loaders, construction machines, loaders, excavators, sweepers, industrial machines and for other applications hydraulically controlled. Recommended oil flow in the system: 0-80L / min. Control example: double-acting hydraulic cylinder. Possibility of series connection to the existing system (requires connection of a pressure sleeve). Three-position lever (1-0-2), spring-loaded, ie it moves back into the vertical position. Neutral position 0 (lever up), piston rod of the hydraulic cylinder is stationary – oil overflows. Working position 1 (lever up), the piston rod of the hydraulic cylinder slides out. Working position 2 (lever up), the piston rod of the hydraulic cylinder retracts. Pump supply (P): female thread BSPP 3/4 ” (Sometimes BSPP 1/2″). Return to tank (T). Female thread BSPP 3/4. Output for sections (A, B). Female thread BSPP 1/2. Pressure range Maximum supply pressure: 250 bar. Maximum return pressure: 50 bar. Maximum pressure in sections: 300bar. Bypass valve (safety) set at the factory to 175 bar. Self-adjusting, full turn 30 bar displacement. Permissible ambient temperature: 40 ° C to + 60 ° C. Permissible oil temperature: 15 ° C to + 80 ° C. Dimensions can be changed slightly.
1x FLOATING 3 Bank Hydraulic Directional Control Valves 80L 21 gpm Double Acting
Comments Off

1x FLOATING spool 4 Bank Hydraulic Directional Control Valve 11gpm 40L 3x DA February 11, 2025

1x-FLOATING-spool-4-Bank-Hydraulic-Directional-Control-Valve-11gpm-40L-3x-DA-01-cb 1x FLOATING spool 4 Bank Hydraulic Directional Control Valve 11gpm 40L 3x DA
1x FLOATING spool 4 Bank Hydraulic Directional Control Valve 11gpm 40L 3x DA
1x FLOATING spool 4 Bank Hydraulic Directional Control Valve 11gpm 40L 3x DA

1x FLOATING spool 4 Bank Hydraulic Directional Control Valve 11gpm 40L 3x DA
NOTE: We issue VAT invoices for countries in the European Union. 4 Spool Hydraulic Directional Control Valve 11gpm 40L. 1x FLOATING Double Acting. 3x Double Acting Cylinder DA. Hydraulic distributors are guaranteed for 2 years. It is used in hydraulic systems in agriculture, horticulture, forestry, construction and industry. The distributor is adapted to different types of machines: agricultural machines, tractors, sprayers, front loaders, construction machines, loaders, excavators, sweepers, industrial machines and for other applications hydraulically controlled. Recommended oil flow in the system: 0-40L / min. Control example: double-acting hydraulic cylinder. Possibility of series connection to the existing system (requires connection of a pressure sleeve). Three-position lever (1-0-2), spring-loaded, ie it moves back into the vertical position. Neutral position 0 (lever up), piston rod of the hydraulic cylinder is stationary – oil overflows. Working position 1 (lever up), the piston rod of the hydraulic cylinder slides out. Working position 2 (lever up), the piston rod of the hydraulic cylinder retracts. Pump supply (P): female thread BSP 1/2. Return to tank (T). Female thread BSP 1/2. Output for sections (A, B). Female thread BSP 3/8. Pressure range Maximum supply pressure: 250 bar. Maximum return pressure: 50 bar. Maximum pressure in sections: 300bar. Bypass valve (safety) set at the factory to 175 bar. Self-adjusting, full turn 30 bar displacement. Permissible ambient temperature: 40 ° C to + 60 ° C. Permissible oil temperature: 15 ° C to + 80 ° C. Dimensions can be changed slightly.
1x FLOATING spool 4 Bank Hydraulic Directional Control Valve 11gpm 40L 3x DA
Comments Off

1 Bank Hydraulic Directional Control Valve 21gpm 80L with FLOATING spool FLOAT February 6, 2025

1-Bank-Hydraulic-Directional-Control-Valve-21gpm-80L-with-FLOATING-spool-FLOAT-01-kvz 1 Bank Hydraulic Directional Control Valve 21gpm 80L with FLOATING spool FLOAT
1 Bank Hydraulic Directional Control Valve 21gpm 80L with FLOATING spool FLOAT
1 Bank Hydraulic Directional Control Valve 21gpm 80L with FLOATING spool FLOAT

1 Bank Hydraulic Directional Control Valve 21gpm 80L with FLOATING spool FLOAT
NOTE: We issue VAT invoices for countries in the European Union. 1 BANK HYDRAULIC MONOBLOCK DIRECTIONAL SPOOL VALVE Double Acting Cylinder DA + floating spool. Hydraulic distributors are guaranteed for 2 years. It is used in hydraulic systems in agriculture, horticulture, forestry, construction and industry. The distributor is adapted to different types of machines: agricultural machines, tractors, sprayers, front loaders, construction machines, loaders, excavators, sweepers, industrial machines and for other applications hydraulically controlled. Recommended oil flow in the system: 0-80L / min. Control example: double-acting hydraulic cylinder. Possibility of series connection to the existing system (requires connection of a pressure sleeve). Three-position lever (1-0-2), spring-loaded, ie it moves back into the vertical position. Neutral position 0 (lever up), piston rod of the hydraulic cylinder is stationary – oil overflows. Working position 1 (lever up), the piston rod of the hydraulic cylinder slides out. Working position 2 (lever up), the piston rod of the hydraulic cylinder retracts. Pump supply (P): female thread BSPP 3/4 ” (Sometimes BSPP 1/2″). Return to tank (T). Female thread BSPP 3/4. Output for sections (A, B). Female thread BSPP 1/2. Pressure range Maximum supply pressure: 250 bar. Maximum return pressure: 50 bar. Maximum pressure in sections: 300bar. Bypass valve (safety) set at the factory to 175 bar. Self-adjusting, full turn 30 bar displacement. Permissible ambient temperature: 40 ° C to + 60 ° C. Permissible oil temperature: 15 ° C to + 80 ° C.
1 Bank Hydraulic Directional Control Valve 21gpm 80L with FLOATING spool FLOAT
Comments Off

1x FLOATING 7 Bank Hydraulic Directional Control Valves 6xDA Double 40L 11gpm ex February 4, 2025

1x-FLOATING-7-Bank-Hydraulic-Directional-Control-Valves-6xDA-Double-40L-11gpm-ex-01-nkl 1x FLOATING 7 Bank Hydraulic Directional Control Valves 6xDA Double 40L 11gpm ex
1x FLOATING 7 Bank Hydraulic Directional Control Valves 6xDA Double 40L 11gpm ex
1x FLOATING 7 Bank Hydraulic Directional Control Valves 6xDA Double 40L 11gpm ex

1x FLOATING 7 Bank Hydraulic Directional Control Valves 6xDA Double 40L 11gpm ex
NOTE: We issue VAT invoices for countries in the European Union. 7 Spool Hydraulic Directional Control Valve 11gpm 40L. 1x FLOATING Double Acting. 6x Double Acting Cylinder DA. 07P40 6xA1 K16 GKZ1. Hydraulic distributors are guaranteed for 2 years. It is used in hydraulic systems in agriculture, horticulture, forestry, construction and industry. The distributor is adapted to different types of machines: agricultural machines, tractors, sprayers, front loaders, construction machines, loaders, excavators, sweepers, industrial machines and for other applications hydraulically controlled. Recommended oil flow in the system: 0-40L / min. Control example: double-acting hydraulic cylinder. Possibility of series connection to the existing system (requires connection of a pressure sleeve). Three-position lever (1-0-2), spring-loaded, ie it moves back into the vertical position. Neutral position 0 (lever up), piston rod of the hydraulic cylinder is stationary – oil overflows. Working position 1 (lever up), the piston rod of the hydraulic cylinder slides out. Working position 2 (lever up), the piston rod of the hydraulic cylinder retracts. Pump supply (P): female thread BSP 1/2. Return to tank (T). Female thread BSP 1/2. Output for sections (A, B). Female thread BSP 3/8. Pressure range Maximum supply pressure: 250 bar. Maximum return pressure: 50 bar. Maximum pressure in sections: 300bar. Bypass valve (safety) set at the factory to 175 bar. Self-adjusting, full turn 30 bar displacement. Permissible ambient temperature: 40 ° C to + 60 ° C. Permissible oil temperature: 15 ° C to + 80 ° C. Dimensions can be changed slightly.
1x FLOATING 7 Bank Hydraulic Directional Control Valves 6xDA Double 40L 11gpm ex
Comments Off

1 Bank Hydraulic Directional Control Valve 21gpm 80L with FLOATING spool ex January 29, 2025

1-Bank-Hydraulic-Directional-Control-Valve-21gpm-80L-with-FLOATING-spool-ex-01-uqo 1 Bank Hydraulic Directional Control Valve 21gpm 80L with FLOATING spool ex
1 Bank Hydraulic Directional Control Valve 21gpm 80L with FLOATING spool ex
1 Bank Hydraulic Directional Control Valve 21gpm 80L with FLOATING spool ex

1 Bank Hydraulic Directional Control Valve 21gpm 80L with FLOATING spool ex
NOTE: We issue VAT invoices for countries in the European Union. 1 BANK HYDRAULIC MONOBLOCK DIRECTIONAL SPOOL VALVE Double Acting Cylinder DA + floating spool. Hydraulic distributors are guaranteed for 2 years. It is used in hydraulic systems in agriculture, horticulture, forestry, construction and industry. The distributor is adapted to different types of machines: agricultural machines, tractors, sprayers, front loaders, construction machines, loaders, excavators, sweepers, industrial machines and for other applications hydraulically controlled. Recommended oil flow in the system: 0-80L / min. Control example: double-acting hydraulic cylinder. Possibility of series connection to the existing system (requires connection of a pressure sleeve). Three-position lever (1-0-2), spring-loaded, ie it moves back into the vertical position. Neutral position 0 (lever up), piston rod of the hydraulic cylinder is stationary – oil overflows. Working position 1 (lever up), the piston rod of the hydraulic cylinder slides out. Working position 2 (lever up), the piston rod of the hydraulic cylinder retracts. Pump supply (P): female thread BSPP 3/4 ” (Sometimes BSPP 1/2″). Return to tank (T). Female thread BSPP 3/4. Output for sections (A, B). Female thread BSPP 1/2. Pressure range Maximum supply pressure: 250 bar. Maximum return pressure: 50 bar. Maximum pressure in sections: 300bar. Bypass valve (safety) set at the factory to 175 bar. Self-adjusting, full turn 30 bar displacement. Permissible ambient temperature: 40 ° C to + 60 ° C. Permissible oil temperature: 15 ° C to + 80 ° C.
1 Bank Hydraulic Directional Control Valve 21gpm 80L with FLOATING spool ex
Comments Off

1x Floating 2 Bank Hydraulic Directional Control Valve 21gpm 80L cable kit ex January 17, 2025

1x-Floating-2-Bank-Hydraulic-Directional-Control-Valve-21gpm-80L-cable-kit-ex-01-fu 1x Floating 2 Bank Hydraulic Directional Control Valve 21gpm 80L cable kit ex
1x Floating 2 Bank Hydraulic Directional Control Valve 21gpm 80L cable kit ex
1x Floating 2 Bank Hydraulic Directional Control Valve 21gpm 80L cable kit ex

1x Floating 2 Bank Hydraulic Directional Control Valve 21gpm 80L cable kit ex
NOTE: We issue VAT invoices for countries in the European Union. Hand control valve Hand lever valve hydraulic 80L / min 2-fold for 1x double-acting cylinder. Controlled with the Bowden cables. It is widely used in hydraulic systems in agriculture, horticulture, forestry, construction, and broader industry. The distributor is adapted to different types of machines, such as B. Agricultural machines, tractors, sprayers, round vehicles, cyclo-loaders, HDS loaders, construction machinery, loaders, excavators, sweepers, industrial machines and other hydraulically controlled devices. Recommended system oil flow: 0 – 80 l / min. Example control: 2-sided drive. Can be connected in series to an existing system (pressure sleeve required). Three-position lever (1 – 0 – 2), spring-loaded, ie it moves back into the vertical position. Neutral position 0 (lever up), piston rod of the hydraulic cylinder is stationary – oil overflows. Working position 1 (lever up), the piston rod of the hydraulic cylinder slides out. Working position 2 (lever up), the piston rod of the hydraulic cylinder retracts. Four-position lever (1 – 0 – 2 – 3), three positions (1 – 0 – 2) on spring (lever goes back to vertical position), position (3) on spring clip (lever stops in floating position). Position 0 neutral (lever in vertical position) The actuator piston rod is stationary – oil overflows. Position 1 (lever in front inclined position) The cylinder piston rod slides out. Position 2 (lever in diagonal reverse position) the piston rod retracts. Position 3 floating with latch (lever in maximum forward position) The piston rod loosens, pulls out and moves in freely under the action of force. Pump supply (P): female thread BSP 1/2” or BSP 3/4′. Return to tank (T): female thread BSP 3/4. Output for sections (A, B): Female thread BSP 1/2. Series connection (N): Female thread BSP 3/4. Maximum inlet pressure: 250bar Maximum return pressure: 50bar Maximum pressure on sections: 300bar. Factory-set overflow valve to 175 bar Self-adjusting, full turn, change by 30 bar. Wide lever configuration options (examples in picture). Recommended oil temperature range. Permissible ambient temperature: -40 ° C to +60 ° C Permissible oil temperature: -15 ° C to +80 ° C.
1x Floating 2 Bank Hydraulic Directional Control Valve 21gpm 80L cable kit ex
Comments Off

1 x FLOATING spool 2 Bank Hydraulic Directional Control Valve 11gpm 40L January 15, 2025

1-x-FLOATING-spool-2-Bank-Hydraulic-Directional-Control-Valve-11gpm-40L-01-ubyb 1 x FLOATING spool 2 Bank Hydraulic Directional Control Valve 11gpm 40L
1 x FLOATING spool 2 Bank Hydraulic Directional Control Valve 11gpm 40L
1 x FLOATING spool 2 Bank Hydraulic Directional Control Valve 11gpm 40L

1 x FLOATING spool 2 Bank Hydraulic Directional Control Valve 11gpm 40L
NOTE: We issue VAT invoices for countries in the European Union. 2 Spool Hydraulic Directional Control Valve 11gpm 40L 1. X FLOATING Double Acting. Hydraulic distributors are guaranteed for 2 years. It is used in hydraulic systems in agriculture, horticulture, forestry, construction and industry. The distributor is adapted to different types of machines: agricultural machines, tractors, sprayers, front loaders, construction machines, loaders, excavators, sweepers, industrial machines and for other applications hydraulically controlled. Recommended oil flow in the system: 0-40L / min. Control example: double-acting hydraulic cylinder. Possibility of series connection to the existing system (requires connection of a pressure sleeve). Three-position lever (1-0-2), spring-loaded, ie it moves back into the vertical position. Neutral position 0 (lever up), piston rod of the hydraulic cylinder is stationary – oil overflows. Working position 1 (lever up), the piston rod of the hydraulic cylinder slides out. Working position 2 (lever up), the piston rod of the hydraulic cylinder retracts. Pump supply (P): female thread BSP 1/2. Return to tank (T). Female thread BSP 1/2. Output for sections (A, B). Female thread BSP 3/8. Pressure range Maximum supply pressure: 250 bar. Maximum return pressure: 50 bar. Maximum pressure in sections: 300bar. Bypass valve (safety) set at the factory to 175 bar. Self-adjusting, full turn 30 bar displacement. Permissible ambient temperature: 40 ° C to + 60 ° C. Permissible oil temperature: 15 ° C to + 80 ° C.
1 x FLOATING spool 2 Bank Hydraulic Directional Control Valve 11gpm 40L
Comments Off

1x FLOATING 7 Bank Hydraulic Directional Control Valves 6x DA Double 40L 11 gpm January 8, 2025

1x-FLOATING-7-Bank-Hydraulic-Directional-Control-Valves-6x-DA-Double-40L-11-gpm-01-kzgd 1x FLOATING 7 Bank Hydraulic Directional Control Valves 6x DA Double 40L 11 gpm
1x FLOATING 7 Bank Hydraulic Directional Control Valves 6x DA Double 40L 11 gpm
1x FLOATING 7 Bank Hydraulic Directional Control Valves 6x DA Double 40L 11 gpm

1x FLOATING 7 Bank Hydraulic Directional Control Valves 6x DA Double 40L 11 gpm
NOTE: We issue VAT invoices for countries in the European Union. 7 Spool Hydraulic Directional Control Valve 11gpm 40L. 1x FLOATING Double Acting. 6x Double Acting Cylinder DA. 07P40 6xA1 K16 GKZ1. Hydraulic distributors are guaranteed for 2 years. It is used in hydraulic systems in agriculture, horticulture, forestry, construction and industry. The distributor is adapted to different types of machines: agricultural machines, tractors, sprayers, front loaders, construction machines, loaders, excavators, sweepers, industrial machines and for other applications hydraulically controlled. Recommended oil flow in the system: 0-40L / min. Control example: double-acting hydraulic cylinder. Possibility of series connection to the existing system (requires connection of a pressure sleeve). Three-position lever (1-0-2), spring-loaded, ie it moves back into the vertical position. Neutral position 0 (lever up), piston rod of the hydraulic cylinder is stationary – oil overflows. Working position 1 (lever up), the piston rod of the hydraulic cylinder slides out. Working position 2 (lever up), the piston rod of the hydraulic cylinder retracts. Pump supply (P): female thread BSP 1/2. Return to tank (T). Female thread BSP 1/2. Output for sections (A, B). Female thread BSP 3/8. Pressure range Maximum supply pressure: 250 bar. Maximum return pressure: 50 bar. Maximum pressure in sections: 300bar. Bypass valve (safety) set at the factory to 175 bar. Self-adjusting, full turn 30 bar displacement. Permissible ambient temperature: 40 ° C to + 60 ° C. Permissible oil temperature: 15 ° C to + 80 ° C. Dimensions can be changed slightly.
1x FLOATING 7 Bank Hydraulic Directional Control Valves 6x DA Double 40L 11 gpm
Comments Off

1x FLOATING spool 3 Bank Hydraulic Directional Control Valve 11gpm 40L 2x DA ex January 1, 2025

1x-FLOATING-spool-3-Bank-Hydraulic-Directional-Control-Valve-11gpm-40L-2x-DA-ex-01-ipw 1x FLOATING spool 3 Bank Hydraulic Directional Control Valve 11gpm 40L 2x DA ex
1x FLOATING spool 3 Bank Hydraulic Directional Control Valve 11gpm 40L 2x DA ex
1x FLOATING spool 3 Bank Hydraulic Directional Control Valve 11gpm 40L 2x DA ex

1x FLOATING spool 3 Bank Hydraulic Directional Control Valve 11gpm 40L 2x DA ex
NOTE: We issue VAT invoices for countries in the European Union. 3 Spool Hydraulic Directional Control Valve 11gpm 40L. 1x FLOATING Double Acting. 2x Double Acting Cylinder DA. Hydraulic distributors are guaranteed for 2 years. It is used in hydraulic systems in agriculture, horticulture, forestry, construction and industry. The distributor is adapted to different types of machines: agricultural machines, tractors, sprayers, front loaders, construction machines, loaders, excavators, sweepers, industrial machines and for other applications hydraulically controlled. Recommended oil flow in the system: 0-40L / min. Control example: double-acting hydraulic cylinder. Possibility of series connection to the existing system (requires connection of a pressure sleeve). Three-position lever (1-0-2), spring-loaded, ie it moves back into the vertical position. Neutral position 0 (lever up), piston rod of the hydraulic cylinder is stationary – oil overflows. Working position 1 (lever up), the piston rod of the hydraulic cylinder slides out. Working position 2 (lever up), the piston rod of the hydraulic cylinder retracts. Pump supply (P): female thread BSP 1/2. Return to tank (T). Female thread BSP 1/2. Output for sections (A, B). Female thread BSP 3/8. Pressure range Maximum supply pressure: 250 bar. Maximum return pressure: 50 bar. Maximum pressure in sections: 300bar. Bypass valve (safety) set at the factory to 175 bar. Self-adjusting, full turn 30 bar displacement. Permissible ambient temperature: 40 ° C to + 60 ° C. Permissible oil temperature: 15 ° C to + 80 ° C. Dimensions can be changed slightly.
1x FLOATING spool 3 Bank Hydraulic Directional Control Valve 11gpm 40L 2x DA ex
Comments Off